  1. Click ‘Get Form’ to open the can ulc s537 download in the editor.
  2. Begin by entering the Electrical Permit Number and Date at the top of the form. This information is crucial for tracking and verification purposes.
  3. Fill in the Building Name & Address, ensuring accuracy as this identifies where the fire alarm system is installed.
  4. Indicate the New FAS System Manufacturer and Existing FAS Model Number. This helps in assessing compatibility and compliance with standards.
  5. Complete each verification statement regarding system operation, modifications, and deficiencies by selecting 'Yes' or 'No' as applicable.
  6. In the Certification section, ensure that all technician details are filled out accurately, including names and contact information.
  7. Review all entries for completeness before saving or exporting your completed form for submission.

Start using our platform today to streamline your document editing and form completion process for free!

be ready to get more

Complete this form in 5 minutes or less

Get form

Got questions?

We have answers to the most popular questions from our customers. If you can't find an answer to your question, please contact us.
Contact us
If there is someone living there you can call in a wellness check and police may visit and break in to check on them and verify why the no one is shutting off the alarm. Contact police on the non-emergency number and explain you want to ask for a wellness check and they will put you through to the relevant officer.
Like wired smoke detection systems, wireless smoke detectors are code compliant when they meet NFPA standards. The NFPA 72 sets out certain requirements for wireless smoke detector manufacturing, installation and testing which must be met in order to be code compliant.
The CAN/ULC S537 specifies the verification process for the correct installation and operation of fire alarm systems. This includes testing and checking all parts of the system, such as detectors, control panels or signaling devices, to ascertain their proper functioning ing to relevant codes and standards.
1.1 This Standard prescribes requirements for the inspection and testing of fire alarm systems; and specifies the devices and functions to be inspected, tested, and documented for the periodic inspection and test.
This Standard applies to the inspection, testing and maintenance of smoke alarms within dwelling units as well as within sleeping rooms / areas that are not part of dwelling units. (Refer to Appendix A, Explanatory Materials, Clause A1. 1 and Appendix B, Enhancement of Fire Safety in Residential Occupancies.)
be ready to get more

Complete this form in 5 minutes or less

Get form

People also ask

1.1 This Standard prescribes inspection and test procedures for the purpose of verifying that the fire alarm system is installed in conformance with the design and CAN/ULC-S524, Standard for Installation of Fire Alarm Systems, and performs all of its intended functions as designed.
1.1 This Standard describes the requirements for the design and installation of a fire alarm system with or without voice communication capability, as defined in Section 3, Glossary. NOTE 1: This Standard is intended to apply to both required and voluntary fire alarm installations.
Under CAN/ULC-S553, Installation of Smoke-Alarms standard, interconnected smoke alarms are installed to operate in combination with other smoke-alarms to provide common signalling on all smoke-alarms such that activation of one smoke-alarm will cause all connected smoke- alarms to sound. While the referenced

representative report