It is estimated that 50% of newly constructed homes will fail the blower door or air-tightness test. Most blower door test failures occur because of a lack of understanding of what is necessary to create a continuous air barrier system.
What is the formula for the blower door test?
Lets use an example house that is 25 wide by 40 long by 10 high. This home has a volume of 10,000 cubic feet. Performing a blower door test on this structure produced a result of 167 CFM. To calculate the ACH50 number, we use the formula (CFM50 x 60 minutes)/volume.
How to do a blower door test yourself?
Confirm that all open-flame areas are extinguished and dampers are closed. Create an airflow path. Turn off any gas appliances. Mount the blower door into one of the exterior openings. Take an outdoor pressure reading. Turn on the fan and run the test. Inspect for leaks. Make repairs.
How is a blower door test performed?
During this test, a calibrated fan is installed in an otherwise sealed door or window, while all the other openings to the exterior are closed. When the fan is turned on, it creates a pressure difference between the outside and the inside.
test blower door form
Test blower door form pdfFree test blower door formTest blower door form 2021
Security and compliance
At DocHub, your data security is our priority. We follow HIPAA, SOC2, GDPR, and other standards, so you can work on your documents with confidence.
Blower door panels: A commercial blower door panel, such as those used for HVAC leak testing, is recommended for CPM testing. These usually have an adjustable
Testing shall be conducted with a blower door at a test pressure of 0.2 inches w.g. (50 Pa). Doors and windows of adjacent dwelling units (including top and