- Click ‘Get Form’ to open the ASTM F2170 PDF in the editor.
- Begin by verifying that your relative humidity measuring instrument conforms to section 6 of ASTM F2170-11. This ensures accurate readings.
- Ensure the concrete floor slab and the air space above it have been at service temperature and relative humidity for at least 48 hours before testing.
- Record the total area of the concrete slab and determine the number of test holes required based on slab thickness. Document this information in the designated fields.
- Drill and prepare test holes as per section 10.3 of ASTM F2170-11, noting their locations on a site map within the form.
- Verify that a 72-hour moisture equilibrium period has been achieved for each test hole before proceeding with measurements.
- Perform relative humidity measurements according to section 10.5, ensuring all data is accurately recorded in the provided fields.
Start using our platform today to streamline your document editing and form completion for free!
Fill out astm f2170 pdf online
It's free
It's free
See more astm f2170 pdf versions
We've got more versions of the astm f2170 pdf form. Select the right astm f2170 pdf version from the list and start editing it straight away!
| Versions | Form popularity | Fillable & printable |
|---|---|---|
| 2018 | 4 Satisfied (56 Votes) |
Got questions?
We have answers to the most popular questions from our customers. If you can't find an answer to your question, please contact us.
Contact us
What is the moisture test that is specified by ASTM F2170?
The in-situ Relative Humidity test for concrete measures the amount of moisture vapor present in a concrete slab. The RH percentage value provides an indication of the moisture content within the concrete. The ASTM F2170 standard is a procedure with set specifications on how to perform this test correctly.
What is the ASTM standard for moisture content of concrete?
Acceptable moisture levels in concrete according to ASTM standard, when testing via ASTM F2170, the RH level of a concrete slab needs to be at or below 75% unless the flooring system manufacturer provides alternate guidelines. Some flooring system manufacturers have products that can handle 95% RH or more.
What is ASTM F2170?
The ASTM F2170 standard specifies the use of relative humidity (RH) in situ probes to measure the internal moisture condition of a concrete slab.
What is the ASTM standard for humidity test?
ASTM D2247 Water Resistance Humidity Testing. ASTM D2247 water resistance humidity testing evaluates the effectiveness of coatings in a 100% relative humidity environment.